Support Support

What information does the info message provide for the CAN modules?

The "Info message" option can be used to send signals about the device type, device status, software version as well as serial number and the internal temperature of the measuring module. The data are transmitted in a separate message (additional bus load).

Representation of the signals in the measuring software:

Info message

Signalname Description CSM CAN modules (without HV BM) HV BM modules
_devicename_Device Name of the device X X
_devicename_SN Serial number X X
_devicename_Status Status information X X
_devicename_Major Firmware number before the dot X -
_devicename_Minor Firmware number after the dot X -
_devicename_PTLo Internal temperature of the module
(not supported by all modules)
X -
_devicename_Temp_Dev Device temperature - X
_devicename_Tep_Shunt Shunt temperature - X

BM Temperatures

Signal name Description
_devicename_Temp_Shield Shunt temperature for the shunt of the shield measurement
_devicename_Temp_L1 Shunt temperature phase 1
_devicename_Temp_L2 Shunt temperature phase 2
_devicename_Temp_L3 Shunt temperature phase 3