Skip to main content

Support Support

What has to be considered when updating the firmware of the ECM modules?

Please note the following points when updating the firmware of the ECM modules:

  • Never interrupt the power supply during the update.
  • The firmware can only be updated for one ECM module at a time.
  • There must not be any further modules on the CAN bus (this also apllies to ECM modules).
  • The correct firmware for the module must be selected. The configuration tool does not check the plausibility of the correct firmware file.
  • No probe connected to the module
  • After the successful update, wait until the module has been restarted and is ready for operation (red LED flashes every 2 seconds; configuration tool will show error 0x14 intentionally - sensor missing).