The offset correction via adjustment in CSMconfig takes place in the DBC/A2L file and not in the module. This means that new scaling values are stored in the DBC/A2L file after the offset adjustment has been carried out. If an offset correction is desired during the measurement, it is better to use a function of the measurement software.
The only exception: Remote zero adjustment via CAN message with particular revsions of CAN ADMM8 pro/ADMM8 pro2 .