Support Support

How to achieve Auto Offset (zero adjuustment) via CAN-ID?

This function is only available for the following CAN module types:

  • AD4 MC10 (ADMM 4) HW Rev. G400 and subsequent revisions
  • AD8 MC2 (ADMM 8 pro) HW Rev. D000 and subsequent revisions
  • AD8 MD2 (ADMM 8 pro2) HW Rev. G400
  • CNT 4 evo HW Rev. B

To be able to use this function, it must be activated in the program settings of CSMconfig. Open the settings and activate the following entry: Allow module internal adjustment procedures. The adjustment of the zero point takes place (and only with this AD MM) in the module. This means that changing the offset setting does not change the DBC file.