Note: To use high-speed measurement rates (sampling rates greater than 10 kHz) with CSM ECAT modules, the ECAT operating mode must be set to "10 kHz or packed" in the XCP gateway.
The maximum possible number of modules depends significantly on the selected sampling rate.
The following table applies if all modules of the measurement chain are configured at the same rate:
Sampling Rate | Max. Number of Modules | Max. Number of Channels |
---|---|---|
10 kHz | 25 × ECAT STGMM 6 | 150 channels |
25 × AD4 ECAT MM | 100 channels | |
100 kHz | 11 × AD4 ECAT MM | 44 channels |
1000 kHz | 1 × AD4 ECAT MM | 4 channels |
Mixed high speed measuring rates can only be used in combination with the XCP version 1.4 format. To do this, set the XCP compatibility accordingly in the CSMconfig program settings. The combination possibilities of modules with different sampling rates are almost unlimited. Therefore, the maximum number of modules for two combinations is listed in the following table as an example:
Max. Number of Modules | Sampling Rate | Max. Number of Channels |
---|---|---|
1 × AD4 ECAT MM | 1000 kHz | 4 channels |
100 kHz | 4 channels | |
10 kHz | 4 channels | |
1 × AD4 ECAT MM + 11 × AD4 ECAT MM | 1000 kHz | 4 channels |
10 kHz | 44 channels |
The CSMconfig configuration software provides feedback when configuring an ECAT measurement chain:
Overload configurations are easy to detect and prevent because a warning message appears if the permissible CAN bus load is exceeded.
Questions and answers on CSM products.
Questions and answers on CSM CAN Modules.
Questions and answers on ECAT Measurement modules.
Questions and answers on Exhaust measurement modules.
Questions and answers on our software CSMconfig.
Questions and answers on UniCAN data loggers.
Questions and answers on our software INCA AddOn CAN/ETH.